当前位置: 主页 > 产品中心 > B码发生器/TIME CODE GENERATOR > ES-185E GPS主时钟
ES-185E GPS主时钟 发布时间:2021-01-15

The ES-185E is a GPS Master Clock/Time Code Generator. The unit receives accurate time and date information from Global Positioning System satellites and supplies this data to the user in a variety of forms. A 12-channel receiver is employed that is capable of tracking up to twelve satellites simultaneously, although reception of only one is required for time data to be output. ESE's ES-185E offers an accuracy of better than 10nS, and is entirely self-setting. The dual battery backup provides a Coin Cell for backing up the GPS receiver and User settings, and a Gel-Cell for a 4-hour operational backup. The ESE & ASCII outputs are operational when running on battery.

特点:

  • 12-Channel GPS Receiver
  • SMPTE-LTC/EBU, ESE, IRIG-B, ASCII (RS-232 & USB) Time Code Outputs
  • NTP Output Port Option (RJ-45, IPv6)
  • 1 PPS (pulse-per-second) output
  • Front Panel nine digit .56" Yellow LED display
  • Indoor/Outdoor Antenna and 16' cable
  • Automatic Daylight Saving Time Correction
  • Time Zone Offset
  • +/- 10 Second Offset
  • Configuration via RS-232 & USB
  • New PC Control Panel Software Included
  • Dual battery backup (Coin-Cell & Gel-Cell)
  • GPS Lock LED Indicator and TTL output
  • 1.75" Rackmount enclosure
  • 配置选项:
  • Ant GPS Antenna: High Performance GPS Antenna for harsh RF Environments.
    Clear Clear Anodized Front Panel
    DC DC Operation: Requires the unit to be powered from a DC source exclusively, typically +12 to +35 VDC.
    HR Relay Closure: Option "HR" provides a user programmable relay contact closure. The standard contact closure occurs on the Hour and Half Hour. If contact closures at other times are desired, the user can program up to four relay closures using the PC Software, which can be downloaded from the ESE web site. The reed relay is rated at 10 watts maximum resistive load (500 mA switching current) and is intended for control applications only. The relay contacts are accessible on the DB-9 connector.
    J 220 VAC/50 Hz Operation: The unit is configured to operate from 220 VAC line voltage. 117 VAC 50/60 Hz is standard.
    K Provides a 10 MHz output and a 1 KHz output.
    NTP6 NTP Time Server: Network Time Protocol Output with IPv6 & Network Control input via Ethernet (10/100Base-T, RJ-45).
    UL "UL" Approved Power Supply: The unit is supplied with a UL/CSA approved wall mount power supply (90-264 VAC).


咨询:ES-185E GPS主时钟

  • 国家高新技术企业
  • 拥有二十余项软件著作权
  • 通过ISO9001质量管理体系和国军标质量管理体系认证
  • 拥有卫星测控综合基带及导航测控一体化微带天线两项发明专利